11 OPTION DACS-W Operation Manual
11-2
11.1.2Status Display
A display showing FBC status for FBC option specifications was added and is accessed through the
status display sequence. To access this display continue pressing the INFO key until the FBC Status
Display appears.
11.1.3Preset Parameters
An item for setting FBC was added to the Preset Setting. To access FBC Setting follow the procedures
listed below.
11.1.3.1 FBC
This defines whether or not Feedback Control is activated, meaning that the control pulse count is
continuously reset based on weighing results.
1. Press repeatedly until the FBC status
appears:
WEIGHT VALUE ZOOM → TOTAL
COUNT ZOOM → ACTUAL SPEED ZOOM
→ HISTOGRAM DISPLAY → X-BAR
CHART DISPLAY → LAST 27 WEIGHT
DATA.
When is pressed after LAST 27
WEIGHT DATA, the READY STATUS
DISPLAY appears for setting FBC.
Figure 11-2 Ready Status Display
1. Call up the Preset Setting menu.
2. Press and move the cursor to FBC
Setting.
3. Press .
The FBC Setting display appears.
Figure 11-3 Preset Parameters
Figure 11-4 FBC Setting Menus
0=OFF: Auger filler is controlled by a predetermined pulse count.
INFO
INFO
Tare
* FBC Mean Wt. Dev.
* Control Pulse
*
* FBC ON
10.0
g
-3.2 g
200
ENTER
▼
SELECT
ITEM
Tare
*
* Dynamic Calibration
* FBC Setting
[Preset Setting]
No. 2
10.0 g
FBC
*
* Control Pulse
* FBC Target Wt. 250.0 g
[FBC Setting]
ON
200