DACS-W Operation Manual 11 OPTION
11-5
11.1.3.7 FBC Unused Range -
This defines the average weight value which activates FBC when this weight is not reached. To set FBC
Unused Range - follow the procedures listed below.
11.1.3.8 Sample Count
This defines the number of packs from which to derive the average value. To set Sample Count follow
the procedures listed below.
11.1.3.9 Sample Interval
This defines the interval from when the first pack using a new pulse count is sent until it is check
weighted by DACS. Sampling is not taken during this interval. To set Sample Interval follow the
procedures listed below.
1. Call up the FBC Setting menu.
2. Press and move the cursor to FBC
Unused Range +.
3. Set value via ten-keys.
The setting for FBC Unused Range + is
complete.
Figure 11-11 FBC Setting Menu
1. Call up the FBC Setting menu.
2. Press and move the cursor to FBC
Unused Range -.
3. Set value via ten-keys.
The setting for FBC Unused Range - is
complete.
Figure 11-12 FBC Setting Menu
1. Call up the FBC Setting menu.
2. Press and move the cursor to Sample
Count.
3. Set value via ten-keys.
The setting for Sample Count is complete.
Figure 11-13 FBC Setting Menu
ENTER
* Sample Range + 100.0 g
* Sample Range - 100.0 g
* FBC Unused Range + 1.0 g
[FBC Setting]
ENTER
* FBC Unused Range - 1.0 g
[FBC Setting]
* Sample Count 5
* Sample Interval 2
ENTER
* FBC Unused Range - 1.0 g
[FBC Setting]
* Sample Count 5
* Sample Interval 2