Work safety
WARNING
When work is performed on this system, live parts and unintentional mo-
tions of the robot, positioner or other components can cause injuries
and damage to property. If work is carried out on an operable system,
the main switch on the control cabinet must be turned to the OFF posi-
tion and secured with a padlock to prevent unauthorized persons from
switching it on again.
Warn all persons concerned before putting the system back into opera-
tion.
CAUTION
Risk of burns from hot motors
The motors reach temperatures during operation which can cause
burns.
Avoid contact.
Take appropriate safety precautions, e.g. wear protective gloves.
WARNING
Risk of crushing during removal and installation of motor
When removing or installing the motor, there is a risk of injury by crush-
ing. This could result in hand injuries.
Wear protective gloves.
NOTICE
Wear and premature failure due to damage to toothing
Damage to the toothing of the motor and gear unit can lead to in-
creased wear and premature failure of the components.
During cleaning, ensure that the toothing is not damaged.
Before installation, check the toothing of the motor and gear unit for
damage.
9.5.2.1 Securing the in-line wrist and robot arm
Procedure
1. Secure the in-line wrist and robot arm with a rope sling and attach the
rope sling to the crane hook.
2. Move the crane upwards until the rope sling is taut.
KR IONTEC
266/344 | www.kuka.com MA KR IONTEC V4 | Issued: 11.05.2021
Repair

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kuka IONTEC KR 20 R3100 and is the answer not in the manual?

Kuka IONTEC KR 20 R3100 Specifications

General IconGeneral
Payload20 kg
Reach3100 mm
Repeatability±0.06 mm
Number of Axes6
ControllerKR C4
Protection RatingIP65
Mounting PositionFloor, ceiling, wall

Related product manuals