2MN/2N1
1-3-119
U464 Setting: [Time Interval]
1. Change the setting value using the numeric keys.
2. Press the OK key. The value is set.
Setting: [Mode]
1. Select the item.
Initial setting: Normal
2. Press the OK key. The setting is set.
Setting: [On/Sleep Out]
1. Select On or Off.
Initial setting: On
2. Press the OK key. The setting is set.
Setting: [AP/NE]
1. Select On or Off.
Initial setting: On
2. Press the OK key. The setting is set.
Item No. Description
Display Description
Setting
range
Initial
setting
Time(sec) Setting the interval time of calibration 0 to 9999 (s) 480
Display Description
Short Setting the color print execution mode: short
Normal Setting the color print execution mode: normal
Long Setting the color print execution mode: long
Custom Setting the color print execution mode: custom
Auto Setting the color print execution mode: auto
Display Description
On Executes calibration if fuser temperature is less than 50°C/
122°F at power-up or recovery from auto sleep mode
Off Not to execute calibration regardless of fuser temperature at
power-up or recovery from auto sleep mode
Display Description
On Paper interval calibration at the time of calibration/near end
after toner feed is carried out
Off Paper interval calibration at the time of calibration/near end
after toner feed is not carried out