EasyManuals Logo

Kyocera ECOSYS FS-C8650DN Service Manual

Kyocera ECOSYS FS-C8650DN
546 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #207 background imageLoading...
Page #207 background image
2MN/2N1-1
1-3-139
U906 Resetting partial operation control
Description
Resets the service call code for partial operation control.
Purpose
To be reset after partial operation is performed due to problems in the cassettes or other sec-
tions, and the related parts are serviced.
Method
1. Press the OK key.
2. Press [Execute].
3. Press the OK key to reset partial operation control.
4. Exit the maintenance mode, perform shut-down, and turn the main power switch to off and on
again. Allow more than 5 seconds between Off and On.
U908 Checking the total counter value
Description
Displays the total counter value.
Purpose
To check the total counter value.
Method
1. Press the OK key. The total count value is displayed.
Completion
Press the Back key. The screen for selecting a maintenance item No. is displayed.
U910 Clearing the print coverage data
Description
Clears the accumulated data for the print coverage per A4 size paper and its period of time (as
shown on the service status report).
Purpose
To clear data as required at times such as during maintenance service.
Method
1. Press the OK key.
2. Select [Execute].
3. Press the OK key. The print coverage data is cleared.
Completion
Press the Back key. The screen for selecting a maintenance item No. is displayed.
Item No. Description

Table of Contents

Other manuals for Kyocera ECOSYS FS-C8650DN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kyocera ECOSYS FS-C8650DN and is the answer not in the manual?

Kyocera ECOSYS FS-C8650DN Specifications

General IconGeneral
BrandKyocera
ModelECOSYS FS-C8650DN
CategoryPrinter
LanguageEnglish

Related product manuals