2MN/2N1-1
1-3-147
U952 Method: [Exec(USB)]
1. Perform shut-down on the operation panel, turn power off(see page P.1-2-19).
2. Insert USB memory in USB memory slot.
3. Turn the main power switch on.
4. Enter maintenance item U952.
5. Select [Execute(USB)].
6. Select the workflow.
7. Press the OK key.
Executes maintenance modes defined in a workflow in succession.
Method: [Entry(USB)]
1. Perform shut-down on the operation panel, turn power off (see page p.1-2-19).
2. Insert USB memory in USB memory slot.
3. Turn the main power switch on.
4. Enter maintenance item U952.
5. Select [Entry(USB)].
6. Select the workflow.
7. Select the work flow save area.
8. Select [Execute].
Exports a workflow housed in a USB flash device to the machine.
Example
Registration is feasible when a USB flash device that stores the commands and text/mainte-
nance ID (editable) is inserted.
File Format: xxx.mwf
!R! MNFC “WFPS”;
1.SET UP, 464, 469, 000, 927, 278
2.WARRANTY, 089, 000
3.MK-A, 119, 930, 140, 469, 127, 464, 469, 464, 251
4.MK-B, 119, 930, 140, 464, 469, 464, 251
5.MK-C, 167, 464, 469, 251
WRED;EXIT;
Completion
Press the Back key. The screen for selecting a maintenance item No. is displayed.
Item No. Description
Display Description
Data01 - 06 Workflow data in the USB flash device
Display Description
Data01 - 06 Workflow data in the USB flash device
Display Description
Data1 - 6 The area to store workflows in the machine