2250 SERVICE/MAINTENANCE MANUAL TROUBLESHOOTING
10
PROBLEM 3
Engine runs, but no hydraulic operation.
POSSIBLE CAUSES
Clutch not engaged. No hydraulic fluid in tank. Blocked charge inlet to pumps. Clogged tank vent.
Drive train damaged from flywheel to pump mount.
CHECKS
Check hydraulic filter service shut-off valve.
OK Not OK
Check clutch engagement.
Open filter service shut-off valve or
replace filters if necessary.
Clutch Engaged Clutch Not Engaged
Engage clutch.
Remove tank cap and check vent, fluid level, and viscosity. In extreme cold
conditions, oil may not flow freely to pump inlets causing pump cavitation.
Tank Vent, Oil Level, Viscosity OK Not OK
Service hydraulic system.
Check manual override on two or more pumps. Does engine load when
manual override is applied? Make sure all brakes are applied. (See Te s t
10—Manually Stroking the Pump.)
Pump Loads
Pump Does Not Load
Check electrical input from controller to pump. (See
Test 4—Testing the Pump EDC and Motor PCP
.)
Consult Manitowoc
Crane Care Lattice
Team.

Table of Contents

Other manuals for Manitowoc 2250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Manitowoc 2250 and is the answer not in the manual?

Manitowoc 2250 Specifications

General IconGeneral
BrandManitowoc
Model2250
CategoryConstruction Equipment
LanguageEnglish

Related product manuals