EasyManua.ls Logo

Matrix 0850 - Page 206

Matrix 0850
231 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
0850/0850-T1 User Manual
Matrix Machine Tool (Coventry) Limited 206 / 231
Edition: 08/2013
Drum Lock
The centrifuge unit is equipped with a drum lock function that is used to stop the drum from spinning
when essential maintenance work is required to the centrifuge. Normally, the drum should be set to
the locked position when the drive belts need to be changed or if the drum needs to be operated
manually for cleaning out heavy debris deposits that may still be stuck to the inside wall of the drum.
The drum lock switch is accessed by removing the hexagon cap head screw securing the hinged
access lid. The access lid is fitted with a cut out switch and kills the power to the drive motor when
the lid is opened.
Access to the drum lock
1. Using a hexagon key (allen key) remove the cap head
that secures the hinged access lid.
Lift the access lid and wait until the centrifuge motor has
stopped rotating.
2
CAUTION!
THE DRIVE MOTOR WILL CONTINUE TO RUN
FOR APPROX 4 MINUTES UNTIL IT REACHES
STANDSTILL. DO NOT ATEMPT TO ENGAGE
THE DRUM LOCK WHILST THE DRUM IS STILL
ROTATING OTHERWISE THERE IS A RISK OF
PERSONAL INJURY AND THE LOCKING PIN
WILL GET DAMAGED.
Drum Lock
Drum Pulley
Fig 5
Fig 6
Cut out switch
Fig 6

Table of Contents

Related product manuals