27.2  MELSECNET/10 Connection (PLC To PLC Network)
27.2.10  CNC Side Settings
27 - 39
25
BAR CODE READER 
CONNECTION
26
PRINTER CONNECTION
27
CNC CONNECTION
28
MULTI-CHANNEL 
FUNCTION
29
FA TRANSPARENT 
FUNCTION
30
MULTIPLE-GT11 
CONNECTION FUNCTION
31
GATEWAY FUNCTION INDEX
2 Expansion unit settings
(1) FCU6-EX879 (Optical fiber cable)
*1 Set the network type to the PLC to PLC network.
*2 Set as necessary.
*3 Set the station No. not to overlap with that of other units.
*4 Set the station type to the control station.
*1 For details of the parameter setting, refer to the following.
 MELDAS C6/C64 NETWORK MANUAL BNP-B2373
Switch layout No. Switch name Settings
1)
Condition setting 
switch
Set the operation condition.
SW Description OFF ON
1
Network type
*1
Inter-PC net (PC) Remote I/O net
2
Station type
*4
Normal station 
(N.ST)
Control station 
(MNG)
3
Used parameter
*2
Common parameters 
(PRM)
Default parameter 
(D.PRM)
4
Number of sta-
tions
*2 
(Valid 
when SW3 is 
ON)
OFF
8
sta-
tions
ON
16 
sta-
tions
OFF
32
sta-
tions
ON
64
sta-
tions
5
OFF OFF ON ON
6
B/W total points
*2
 
(Valid when SW3 
is ON)
OFF
2K
poi-
nts
ON
4K
poi-
nts
OFF
6K
poi-
nts
ON
8K
poi-
nts
7
OFF OFF ON ON
8
Not used Always OFF
2)
Station number 
switch
Station number setting
*2*3
<Setting range>
01 to 64: Station number
Other than 01 to 64: Setting error
3)
Settings switch 
of group NO.
Group number setting
Not used, fixed to 0
4)
Settings switch 
of Network NO.
Network number setting
*2
<Setting range>
001 to 255: Network number
Other than 001 to 255: Setting error
5)
Mode setting 
switch
Mode setting
*2
0: Online
1: Cannot be used
2: Offline
3 to F: Test mode
1
2)
3)
4)
5)
1 
8 
7 
6 
5 
4 
3 
2 
ON