27 - 68
27.4 Ethernet Connection
27.4.5 Setting communication interface (Communication settings)
2 Communication detail settings
(Continued to next page)
Item Description Range
GOT NET No.
Set the network No. of the GOT.
<Default: 1>
1 to 239
GOT PC No.
Set the station No. of the GOT.
<Default: 1>
1 to 64
GOT IP Address
Set the IP address of the GOT.
<Default: 192.168.0.18>
0.0.0.0 to 255.255.255.255
GOT Port No.
(QJ71E71/AJ71(Q)E71)
Set the GOT port No. for the connection with the Ethernet module.
<Default: 5001>
1024 to 5010, 5014 to 65534
(Except for 5011, 5012 and 5013)
GOT Port No.
(Ethernet Download)
Set the GOT port No. for Ethernet download.
<Default: 5014>
1024 to 5010, 5014 to 65534
(Except for 5011, 5012 and 5013)
Default Gateway
Set the router address of the default gateway where the GOT is
connected. (Only for communication via router)
<Default: 0.0.0.0>
0.0.0.0 to 255.255.255.255
Subnet Mask
Set the subnet mask for the sub network. (Only for connection via
router)
If the sub network is not used, the default value is set.
<Default: 255.255.255.0>
0.0.0.0 to 255.255.255.255
Retry
Set the number of retries to be performed when a communication
error occurs.
When receiving no response after retries, the communication
times out.
<Default: 3 Times>
0 to 5 Times
Startup Time
Specify the time period from the GOT startup until GOT starts the
communication with the PLC CPU.
<Default: 3 Sec>
3 to 255 Sec