7 Function Code Table NICE3000
new
User Manual
- 172 -
7
Function
Code
Parameter Name Setting Range Default Unit Property Page
F5-26 Y1 function selection
01: RUN contactor control
02: Brake contactor control
03: Shorting door lock circuit
contactor control
04: Fire emergency oor arrival
feedback
Others:
00: Invalid
05: Door 1 open
06: Door 1 close
07: Door 2 open
08: Door 2 close
09: Brake and RUN contactors
healthy
10: Fault state
11: Running monitor
12: Shorting PMSM stator
contactor
13: Emergency evacuation
automatic switchover
14: System healthy
15: Emergency buzzer control
16: Higher-voltage startup of
brake
17: Elevator running in up
direction
18: Lamp/Fan running
19: Medical sterilization
20: Non-door zone stop
21: Electric lock
22: Non-service state
1 -
207
F5-27 Y2 function selection 2 -
207
F5-28 Y3 function selection 3 -
207
F5-29 Y4 function selection 4 -
207
F5-30 Y5 function selection 0 -
207
F5-31 Y6 function selection 0 -
207
F5-32
Communication state
display
- - -
209