• When using rigid media with a soft printing surface, the head height value displayed on Operation
panel may differ from the actual media thickness.
If this happens, see the following and enter the correction value so that the head height matches the
actual media thickness.
• Media thickness detection is a function to keep the gap between Print head and the media, and to
stabilize print quality; the measured value may differ from the actually media thickness.
a. Remove the rigid media from the printer.
b. Measure the media thickness with a tool such as slide gauge.
c. Load the rigid media again.
d. Enter the difference between the value displayed on Operation panel and the actual media
thickness as a correction value.
•The total amount of the head height setting value (thickness) and the input adjustment value (adjustment) is displayed
in "*.*".
•When you press the [>] key on the operation panel, the setting value (*.*) and the input adjustment value ( . ) are each
displayed, as in "Thick. + Adj: *.* + . ".
7. Press the [Enter] key on the operation panel.