Controller-Managed Access Points
380
ProSAFE Wireless Controller
c. Reconfigure the static IP address setting and the VLAN settings or reenable the
DHCP client.
For more information, see Change IP Address and VLAN Settings on a
Controller-Managed Access Point on page 376 and Reenable the DHCP Client on
a Controller-Managed Access Point on page 377.
If you cannot connect to the access point, its IP address might be the factory default
IP address.
• The access point’s IP address is reset to the factory default IP address. Do the
following:
a. Determine the factory default IP address for the model access point.
b. Configure a computer with a static IP address in the same subnet as the factory
default IP address of your model access point and a subnet mask of
255.255.255.0.
c. Use an Ethernet cable to connect the computer to the access point.
d. Log back in to the access point using the factory default IP address of your
model access point.
e. Enter the user name and password.
The user name is admin. The default password is password. The user name and
password are case-sensitive.
f. Select Configuration > Upgrade > Firmware Upgrade.
Access Point Model Factory Default IP Address
WAC740 192.168.0.160
WAC730 192.168.0.100
WAC720 192.168.0.100
WN370 192.168.0.160
WND930 192.168.0.100
WNDAP660 192.168.0.100
WNDAP620 192.168.0.100
WNDAP380R Not applicable
1
1. The WNDAP380R does not provide a web
management interface and a default IP address.
The WNDAP380R can be managed only by a
wireless controller in a network with a DHCP server.
WNDAP360 192.168.0.100
WNDAP350 192.168.0.237
WNAP320 192.168.0.100
WNAP210v2 192.168.0.236