3-41
Function No. Name Description Setting
range
Refer-
ence
page
Motor rotation
direction selec-
tion
n005 Forward/Re-
verse rotation
selection
0: When the forward rotation command is
input, the motor seen from the load
side rotates counterclockwise.
1: When the forward rotation command is
input, the motor seen from the load
side rotates clockwise.
Note This
parameter is
not initialized when
parameter initialization is performed
by
setting n001 to 6 or 7. (It is only
ini
-
tialized when a CPF4 error is
detected.)
0, 1 [0] 3-17
n006 Reverse rota-
tion-inhibit
selection
0: The motor can rotate in reverse.
1: The motor cannot rotate in reverse.
0, 1 [0] 3-17