XtraDrive User Manual Appendix B: Special Wiring
B-6
Noise on the Reference Input Line
If the reference input line is affected by noise, ground the 0V line (SG)
of the reference input line. If the main circuit wiring for the motor is
accommodated in a metal conduit, ground the conduit and its junction
box.
All grounds must be made to only one point in the system.
Using Noise Filters
Use a noise suppression filter to prevent noise generated by the power
supply line. Install a noise filter on the power supply line for peripheral
equipment as necessary.
The following table recommends noise filters for each servo amplifier
model.
Recommended Noise Filter
Voltage Servo Amplifier Model
Model Manufacturer
XD - P3 to XD - 02 FN2070-6/07
XD - 04 FN2070-10/07
XD - 08 FN2070-16/07
Single-phase,
200V
XD -15 FN350-30/33
XD -10 FN258L-7/07 Three-phase,
400V
XD -20, 30 FN258L-16/07
Schaffner
Note: Filters manufactured by Schaffner.