Automatic Operation (Synchronous Control)
8-22
Cam table adjustments
The Cam Table settings screen is provided with a function to make the fine-tuning of set cam
curve data. In order to mitigate radical changes, this adjustment function makes it possible to
fine-tune cam data that has been set. To make adjustments, select the target section number
and press the [Adjust] button. The adjustment screen is displayed. The Adjustment screen
displays the tables corresponding to the numbers of the designated sections out of all the
sections (0% to 100%) divided by the resolution.
Select the data on the target phases (control points) and change the corresponding
displacement data. The adjustments will be reflected by selecting [OK] and the set adjustment
data will be cleared by selecting [Adjustment clear]. The numbers of the adjusted sections
where the cam curve adjustments have been made are displayed in red, which tells that the
adjustments have been completed.
Adjusted data
(displayed in red)