Specifications
17-8
Contact
allocation
Target axis Name Description
WX4
X40
|
X47
− − −
X48 1st axis
Auxiliary
contact
Turns ON when the corresponding positioning table of the corresponding
axis is executed.
X49 2nd axis
X4A 3rd axis
X4B 4th axis
X4C
|
X4E
− − −
X4F
Virtual
axis
Auxiliary
contact
Turns ON when the corresponding positioning table of the virtual axis is
executed.
WX5
X50
1st axis
Limit + Monitor contact of the limit + and –.
Decelerates to stop when the limit input that is on an extension of the
operating direction turns ON while the positioning unit is in positioning
operation, JOG operation, or pulser operation.
The deceleration stop time during the limit input can be changed in the unit
memory.
It will be the contact for the automatic inversion when performing a home
return.
The input logic can be changed in the parameter-setting menu of the
Configurator PM7.
X51 Limit -
X52
2nd axis
Limit +
X53 Limit -
X54
3rd axis
Limit +
X55 Limit -
X56
4th axis
Limit +
X57 Limit -
X58
|
X5F
− − −
WX6
X60 1st axis
Error
annunciation
Turns ON when an error occurs on the corresponding axis.
The contacts of all axes turn ON if all axes have errors.
The details of the error can be confirmed in the error annunciation area of
the unit memory.
X61 2nd axis
X62 3rd axis
X63 4th axis
X64
|
X66
− − −
X67
Virtual
axis
Error
annunciation
Turns ON when an error occurs on the virtual axis.
X68 1st axis
Warning
annunciation
Turns ON when a warning occurs on the corresponding axis.
The contacts of all axes turn ON if a warning occurs on all axes.
The details of the warning can be confirmed in the warning annunciation
area of the unit memory.
X69 2nd axis
X6A 3rd axis
X6B 4th axis
X6C
|
X6E
− − −
X6F
Virtual
axis
Warning
annunciation
Turns ON when a warning occurs on the virtual axis.