17.2 I/O Number Allocation
17-11
Contact
allocation
Target axis Name Description
Y1F Virtual axis Home return start
Requests the home return of the virtual axis. The home return of
the virtual axis is possible only by data setting.
WY2
Y20
1st axis
JOG forward
Requests the JOG operation for the corresponding axis.
(The operation is of level type.)
If this contact turns ON while the positioning unit is in tool
operation, a warning will be output.
Y21 JOG reverse
Y22
2nd axis
JOG forward
Y23 JOG reverse
Y24
3rd axis
JOG forward
Y25 JOG reverse
Y26
4th axis
JOG forward
Y27 JOG reverse
Y28
|
Y2E
Y2E
Virtual axis
JOG forward
Requests the JOG operation of the virtual axis.
(The operation is of level type.)
Y2F JOG reverse
WY3
Y30 1st axis
Emergency stop
Requests the emergency stop of the corresponding axis.
(The operation is of level type.)
Note) The deviation counter cannot be cleared.
Y31 2nd axis
Y32 3rd axis
Y33 4th axis
Y34
|
Y36
Y37 Virtual axis Emergency stop Requests the emergency stop of the virtual axis.
Y38 1st axis
Deceleration stop
Requests the deceleration stop of the corresponding axis.
(The operation is of level type.)
Note) The deviation counter cannot be cleared.
Y39 2nd axis
Y3A 3rd axis
Y3B 4th axis
Y3C
|
Y3E
Y3F Virtual axis Deceleration stop Requests the principle stop of the virtual axis.