Specifications
17-12
Contact
allocation
Target axis Name Description
WY4
Y40 1st axis
Pulser
operation
enabled
Requests the permission for the pulser operation of the corresponding
axis. (The operation is of level type.)
Y41 2nd axis
Y42 3rd axis
Y43 4th axis
Y44
|
Y46
− − −
Y47
Virtual
axis
Pulser
operation
enabled
Requests the permission for the pulser operation of the virtual axis.
Y48 1st axis
J-point speed
change contact
By turning ON this signal while the positioning unit is in J-point operation,
the speed changes to the target speed in the specified
acceleration/deceleration time and pattern.
(The operation is the edge type.)
Y49 2nd axis
Y4A 3rd axis
Y4B 4th axis
Y4C
|
Y4E
− − −
Y4F
Virtual
axis
J-point speed
change contact
Changes the target speed during the JOG (J-point) positioning of the
virtual axis.
WY5
Y50 1st axis
Servo OFF
request
Turn OFF the servo ON signal for the corresponding axis.
The servo ON signal is turned OFF at the ON edge of this contact.
(The operation is the edge type.)
Y51 2nd axis
Y52 3rd axis
Y53 4th axis
Y54
|
Y57
− − −
Y58 1st axis
J-point
positioning
start
The positioning unit will go to the next table processing when this signal
turns ON during the JOG (J-point) positioning of the corresponding axis.
(The operation is the edge type.)
Y59 2nd axis
Y5A 3rd axis
Y5B 4th axis
Y5C
|
Y5E
− − −
Y5F
Virtual
axis
J-point
positioning
start
The positioning unit will go to the next table processing when this signal
turns ON during the JOG (J-point) positioning of the virtual axis.
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com