Specifications
17-40
Offset
address
Name Default Setting range and description
00AH
Automatic
movement
amount
checking
0
Set an action when the difference between the instruction value and feedback
value exceeds the movement check value at the time of automatic movement
amount check.
0: Error
An error will occur and the operation of the positioning unit will come to a stop
if the difference between the feedback value and reference movement
exceeds the movement check value (threshold).
1: Warning
An error will occur and the operation of the positioning unit will come to a stop
if the difference between the feedback value and reference movement
exceeds the movement check value (threshold).
2: No
No movement amount check is made.