17.6 Details of Each Axis Setting Area in Unit Memory
17-41
Offset
address
Name Default Setting range and description
00BH
Software limit
enabled/
disabled settings
0H
Enables or disables the software limit on each control.
bit Name Default Description
0 Enables/disables
the software limit
for positioning
control
0
0: Disables the software limit
for positioning control
1: Enables the software limit
for positioning control
1 Enables/disables
the software limit
while the
positioning unit
is in home return
operation
0
0: Disables the software limit
for home return control
1: Enables the software limit
for home return control
2 Enable/disable
the software limit
in the JOG
operation
0
0: Disables the software limit
for JOG operation
1: Enables the software limit
for JOG operation
15 to 3 − − −
00CH
Upper limit of
software limit
1,073,741,823
Set the upper limit of the software limit for the absolute coordinates.
Set the following range according to the unit setting.
Pulse: -1,073,741,823 to 1,073,741,823 pulses
μm (0.1 μm): -107,374,182.3 to 107,374,182.3 μm
μm (1 μm): -1,073,741,823 to 1,073,741,823 μm
inch (0.00001 inch): -10,737.41823 to 10,737.41823 inches
inch (0.0001 inch): -107,374.1823 to 107,374.1823 inches
degree (0.1 degree): -107,374,182.3 to 107,374,182.3 degrees
degree (1 degree): -1,073,741,823 to 1,073,741,823 degrees
Any other settings will be errors.
00DH
00EH
Lower limit of
software limit
1,073,741,832
Set the upper limit of the software limit for the absolute coordinates.
Set the following range according to the unit setting.
Pulse: -1,073,741,823 to 1,073,741,823 pulses
μm (0.1 μm): -107,374,182.3 to 107,374,182.3 μm
μm (1 μm): -1,073,741,823 to 1,073,741,823 μm
inch (0.00001 inch): -10,737.41823 to 10,737.41823 inches
inch (0.0001 inch): -107,374.1823 to 107,374.1823 inches
degree (0.1 degree): 0.0 to 359.9 degrees
degree (1 degree): 0 to 359 degrees
Any other settings will be errors.
00FH
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.clrwtr.com - Email: info@clrwtr.com