17.6 Details of Each Axis Setting Area in Unit Memory
17-43
Offset
address
Name Default Setting range and description
018H
Automatic movement
amount check value
10000
Set the threshold to use the automatic check function of movement
amount.
Setting range: 0 to 65536
Default: 10000 (pulses)
019H
− − −
01AH
Automatic movement
amount check
interval
0
Set the interval of automatic movement amount checking in ms .
Setting range: 0 to 32767 (ms)
Default: 0 (ms)