Administrator’s Guide for Polycom HDX Systems
6–8 Polycom, Inc.
Managing Directories with the Polycom HDX Web Interface
The Polycom HDX Web Interface import/export directory feature allows you
to maintain consistency of Polycom HDX system directories in your
organization efficiently. It is particularly useful for administrators managing
multiple systems that call the same locations. You can:
Transfer existing directory entries between Polycom HDX systems
Develop directory entries on one system, save them to your computer, and
then distribute them to other systems
Create localized directory entries
Only Favorites directories can be downloaded. Favorites directory entries are
saved to a PC in
.xml
format only in version 2.6. Version 2.6 or later can import
.csv
files saved in a previous HDX version or
.xml
files saved in version 2.6
or later. However, you cannot import
.xml
files into an older HDX version.
To download a Polycom HDX system directory to your computer using the
Polycom HDX web interface:
1 In your web browser address line, enter the HDX system’s IP address.
2 Go to Utilities > Import/Export Directory.
3 Click HDX —> PC to download the
.xml
file from the Polycom HDX
system.
4 Save the file to a location on your computer.
To upload Polycom HDX system directory entries using the Polycom HDX web
interface:
1 In your web browser address line, enter the HDX system’s IP address.
2 Go to Utilities > Import/Export Directory.
3 Click PC —> HDX.
4 Click Browse and browse to the location of the
.csv
or .
xml
file on your
computer.
5 Click Import Directory to upload the file to the Polycom HDX system.
To create a localized directory entry using the Polycom HDX web interface:
1 In your web browser address line, enter the HDX system’s IP address.
2 Go to Place a Call > Directory.
3 Select an entry.
4 Edit the entry to enter a localized directory entry name in the Localized
Name field, and specify the language for the localized directory entry.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for Polycom HDX 7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom HDX 7000 Series and is the answer not in the manual?

Polycom HDX 7000 Series Specifications

General IconGeneral
Content SharingH.239, People+Content
MicrophonePolycom HDX Microphone Array
Network ProtocolsH.323, SIP
Data StandardsH.239
Video Outputs2 x DVI-I
Operating Temperature0°C to 40°C (32°F to 104°F)
Video StandardsH.264, H.263, H.261
Video ResolutionUp to 1920 x 1080
Audio StandardsG.711, G.722.1, G.729A
CameraPolycom EagleEye Camera
ConnectivityEthernet, ISDN
Video InputsDVI-I
Audio InputsRCA
Audio OutputsRCA
Network Interfaces10/100/1000 Ethernet
Power Supply100-240V AC, 50/60Hz