Administrator’s Guide for Polycom HDX Systems
8–34 Polycom, Inc.
To configure Polycom HDX log management:
1 Do one of the following:
In the local interface, go to System > Admin Settings > General
Settings > Security > Log Management (select if necessary).
In the web interface, go to Admin Settings > General Settings >
Security > Log Management.
2 Configure these settings on the Log Management screen:
To transfer the Polycom HDX log manually:
1 In the local interface, go to System > Admin Settings > General Settings
> Security > Log Management.
2 Specify a folder name.
Setting Description
Current Percent
Filled
Displays how full the log file is, as a percentage of the total
size.
Percent Filled
Threshold
Specifies a threshold for the percent filled value. Reaching
the threshold triggers an alarm, creates a log entry, and
transfers the log if Transfer Frequency is set to Auto at
Threshold. Off disables logging threshold notifications.
Folder Name Specifies the name to give the folder for log transfers.
System Name and Timestamp — Folder name is the
system name and the timestamp of the log transfer, in the
date and time format specified on the Location screen.
For example, if the system name is “Marketing”, the
folder name could be
marketing_MMddyyyymmssSSS
.
Timestamp — Folder name is the timestamp of the log
transfer, in the date and time format specified on the
Location screen, for example
yyyyMMddhhmmssSSS
.
•Custom — Optional folder name for manual log
transfers.
Storage Type Specifies the type of storage device used for log file
transfers.
Transfer
Frequency
Specifies when the logs are transferred:
•Manual — The transfer starts when you select the Start
Log Transfer button, which is visible only on the local
interface. If the log fills before being transferred, new
events overwrite the oldest events.
Auto at Threshold — The transfer starts automatically
when the Percent Filled Threshold is reached.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Other manuals for Polycom HDX 7000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Polycom HDX 7000 Series and is the answer not in the manual?

Polycom HDX 7000 Series Specifications

General IconGeneral
Content SharingH.239, People+Content
MicrophonePolycom HDX Microphone Array
Network ProtocolsH.323, SIP
Data StandardsH.239
Video Outputs2 x DVI-I
Operating Temperature0°C to 40°C (32°F to 104°F)
Video StandardsH.264, H.263, H.261
Video ResolutionUp to 1920 x 1080
Audio StandardsG.711, G.722.1, G.729A
CameraPolycom EagleEye Camera
ConnectivityEthernet, ISDN
Video InputsDVI-I
Audio InputsRCA
Audio OutputsRCA
Network Interfaces10/100/1000 Ethernet
Power Supply100-240V AC, 50/60Hz