Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
RFL DA-91I RFL Electronics Inc.
March 6, 2002 9 (973) 334-3100
15. If you plan to operate the RFL DA-91I module under local control, perform the following
steps; otherwise, go to step 16 for remote control.
a. Set to local control by placing DIP switch SW1-7 in the UP position.
b. Turn service on by placing DIP switch SW1-8 in the UP position.
c. Slide the module into the selected module slot until it is firmly seated and the module
front panel is flush with the top and bottom of the shelf.
d. Go to step 17.
16. If you plan to operate the RFL DA-91I module under remote control, perform the following
steps:
a. Set to local control by placing DIP switch SW1-7 in the UP position.
b. Turn service off by placing DIP switch SW1-8 in the DOWN position.
c. Slide the module into the selected module slot until it is firmly seated and the module
front panel is flush with the top and bottom of the shelf.
d. Wait 15 seconds for the RFL DA-91I module’s parameter settings to be loaded into the
shelf Common Module.
e. Pull the module out of the shelf and set to remote control by placing DIP switch SW1-7
in the DOWN position.
Do not move SW1-8.
f. Slide the module back into the shelf.
g. Verify the module configuration through remote control by issuing a “CONFIG?”
query. See the Remote Control Interface section of this Instruction Data Sheet for an
explanation of the “CONFIG?” response.
h. Turn service on through remote control by issuing a “SRVC=ON” command.
The RFL DA-91I’s operating parameters can now be changed by remote
control. See the Remote Control Interface section of this Instruction Data
Sheet for more information.
i. Go to step 17.
17. On the Module Record Card located to the right of the shelf, record the channel bank type, time
slot, and any other pertinent information.
18. The RFL DA-91I is now installed. If your multiplexer is set up for remote access and control,
you can now change the operating parameters of the module by using simple commands. For
more information on remote access and control, consult your multiplexer operation manual.