Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.
RFL DS-562NC RFL Electronics Inc.
July 5, 2012 5 (973)
334-3100
4. Once the Adapter Module has been selected, set it for the following desired configuration as
applicable:
MA-406IA
Select DCE or DTE mode by installing J2 jumpers
MA-406IB
Select DCE or DTE mode by installing J2 jumpers
MA-407I
No configuration is required for this module.
MA-408I
No configuration is required for this module.
MA-409IA
Select DCE or DTE:
DCE: Set jumpers J1 to J9 to DCE
DTE: Set jumpers J1 to J9 to DTE
MA-410I
DCE: S1-1 to S1-4 (toward “DCE”)
DTE: S1-1 to S1-4 (toward “DTE”)
MA-600
No configuration is required for this module.
MA-620/621
Select Normal or Inverted Data:
Normal Data: SW1-1 (DOWN) ON
Inverted Data: SW1-1 (UP) OFF
MA-427
Refer to Table 16 for details on the DIP switch (SW2) settings for this I/O type.
MA-428
Refer to Table 23 for details on the DIP switch (SW2) settings for this I/O type.
5. Insert the Adapter Module into the rear of the shelf directly behind the module slot where the
DS-562NC will be installed. Secure the module with the two screws provided.
6. Connect the Adapter Module to the user equipment using the connector pin assignments
detailed in Tables 1, 2, 3, 4, 5, or 6 as applicable.
7. Refer to Figure 7 for the location of switches on the DS-562NC. Perform the following series
of switch settings with the DS-562NC removed from the motherboard.