Because RFL™ and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specifications without notice.
MA-301D The MA-301D provides pluggable terminal block connections for a single
VF-5A module. Tip and Ring test points are available for the inputs and
outputs of channels 1 and 2. Audio and signaling connections are available
at the terminal block. No additional SWC or fast transient protection is
provided on this I/O. Refer to Figure 5 for panel view and terminal
connections.
RFL VF-5A RFL Electronics Inc.
June 28, 2005 6 (973)
334-3100
SIGNAL TB#
AIN-1T 1
AIN-1R 2
AOUT-1T 3
AOUT-1R 4
M-LEAD-CH1 5
SB-LEAD-CH1 6
E-LEAD-CH1 7
SG-LEAD-CH1 8
AIN-2T 9
AIN-2R 10
AOUT-2T 11
AOUT-2R 12
M-LEAD-CH2 13
SB-LEAD-CH2 14
E-LEAD-CH2 15
SG-LEAD-CH2 16
Figure 5. MA-301D Module Adapter
MA-322 The MA-322 accepts a 50-pin Telco connector (Amphenol 57-30500
or equivalent, as shown in Figure 6.) One MA-322 Module Adapter
is used for each RFL VF-5A module, and occupies two rear slots in
the IMUX 2000 chassis. The MA-322 is used to convert both of the
4-wire outputs (Channel 1 and 2) from 4-wire to 2-wire. The
impedance is 600 Ohms, the frequency response is ±2dB from 200Hz
to 3000Hz,
and the transformer loss (hybrid loss) is ≅ 4.0dB.
MA-324
The MA-324 accepts a 50-pin Telco connector (Amphenol 57-30500
or equivalent, as shown in Figure 6.) One MA-324 Module Adapter
is used for each RFL VF-5A module and occupies two rear slots in
the IMUX 2000 chassis. The MA-324 is used to convert one of the
4-wire outputs (Channel 1) from 4-wire to 2-wire. The other 4-wire
output (Channel 2) remains 4-wire. The impedance is 600 Ohms,
the frequency response is ±2dB from
200Hz
to 3000Hz, and the
transformer loss (hybrid loss) is ≅ 4.0dB.
CH2 CH1
1 T
IN
R
T
OUT
R
M
SB
E
SG
T
IN
R
T
OUT
R
M
SB
E
16 SG
TERMINAL BLOCK
LABEL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
MA301D
MONITOR
T R
IN
1
OUT
CH
IN
2
OUT