Because RFL and Hubbell® have a policy of continuous product improvement, we reserve the right to change designs and specications without notice.
RFL NCM RFL Electronics Inc.
November 1, 2012 46 (973) 334-3100
Table 7. Remote status messages (“S” codes)
S Code Digit(s) And Switch Equivalent Value
(1)
Description
S01
B 0 0 0 0 0 0 0 0
111xxxxx RS-232 Not Installed
110xxxxx Ethernet
I/O TYPE ID
101xxxxx RS-485 4-Wire
100xxxxx RS-485 2-Wire
PORT 1 AVAILABILITY
xxx0xxxx Port 1 Available
xxx1xxxx Port 1 Not Available
PORT 2 AVAILABILITY
xxx0xxxx Port 2 Available
xxx1xxxx Port 2 Not Available
PORT 1 EQUIPMENT LOOPBACK
STATUS
xxxx01xx Port 1 Equipment Loopback Active
xxxx00xx Port 1 Equipment Loopback Inactive
xxxx11xx Port 1 Equipment Loopback Inactive
xxxx10xx Port 1 Equipment Loopback Inactive
PORT 1 PAYLOAD LOOPBACK STATUS
xxxx10xx Port 1 Payload Loopback Active
xxxx01xx Port 1 Payload Loopback Inactive
xxxx00xx Port 1 Payload Loopback Inactive
xxxx11xx Port 1 Payload Loopback Inactive
PORT 2 EQUIPMENT LOOPBACK
STATUS
xxx001xx Port 2 Equipment Loopback Active
xxx000xx Port 2 Equipment Loopback Inactive
xxx010xx Port 2 Equipment Loopback Inactive
xxx011xx Port 2 Equipment Loopback Inactive
xxx100xx Port 2 Equipment Loopback N/A
xxx101xx Port 2 Equipment Loopback N/A
xxx110xx Port 2 Equipment Loopback N/A
xxx111xx Port 2 Equipment Loopback N/A
PORT 2 PAYLOAD LOOPBACK STATUS
xxx011xx Port 2 Payload Loopback Active
xxx001xx Port 2 Payload Loopback Inactive
xxx000xx Port 2 Payload Loopback Inactive
xxx010xx Port 2 Payload Loopback Inactive
xxx100xx Port 2 Payload Loopback N/A
xxx101xx Port 2 Payload Loopback N/A
xxx110xx Port 2 Payload Loopback N/A
xxx111xx Port 2 Payload Loopback N/A
MUX TYPE & CONFIGURATION STATUS
xxxxxx1x E1 Mux
xxxxxx0x T1 Mux
xxxxxxx1 Configuration is Valid
xxxxxxx0 Configuration is Invalid/MUX Problems
>> table continues on next page <<