BIT SWITCHES
B620 24 B620
…continued
System Switch 04 SP No. 1-101-005
No FUNCTION COMMENTS
6
G3 CSI/G4 Terminal ID
programming level
0: User level
1: Service level
1: The CSI and Terminal ID can only be
programmed by a technician (in the user tools).
The Terminal ID can only be programmed if a Group
4 option is installed. This machine does not have a
Group 4 option.
7
Telephone line type
programming mode
0: User level
1: Service level
1: Telephone line type selection (choosing tone dial
or pulse dial) can only be programmed by a
technician (in the user tools).
System Switch 05 - Not used (Do not change the factory settings.)
System Switch 06 - Not used (Do not change the factory settings.)
System Switch 07 - Not used (Do not change the factory settings.)
System Switch 08 - Not used (Do not change the factory settings.)
System Switch 09 SP No. 1-101-010
No FUNCTION COMMENTS
0 Not used Do not change the setting.
1
Inclusion of communications on
the Journal when no image
data was exchanged.
0: Disabled 1: Enabled
0: Communications that reached phase C (message
tx/rx) of the T.30 protocol are listed on the Journal.
1: Communications that reached phase A (call
setup) of T.30 protocol are listed on the Journal.
This will include telephone calls.
2
Automatic error report printout
0: Disabled 1: Enabled
0: Error reports will not be printed.
1: Error reports will be printed automatically after
failed communications.
3
Printing of the error code on the
error report
0: No 1: Yes
1: Error codes are printed on the error reports.
4 Not used Do not change the setting.
5
Power failure report
0: Disabled 1: Enabled
1: A power failure report will be automatically printed
after the power is switched on if a fax message
disappeared from the memory when the power was
turned off last.
6
Conditions for printing the
protocol dump list
0: Print for all communications
1: Print only when there is a
communication error
This switch becomes effective only when system
switch 00 bit 6 is set to 1.
1: Set this bit to 1 when you wish to print a protocol
dump list only for communications with errors.
7
Priority given to various types
of remote terminal ID when
printing reports
0: RTI > CSI > Dial label > Tel.
number
1: Dial label > Tel. number >
RTI > CSI
This bit determines which set of priorities the
machine uses when listing remote terminal names
on reports.
Dial Label: The name stored, by the user, for the
Quick/Speed Dial number.
Rev.09/2005