12 The modem board could
not enable the NIB.
Replace the modem board.
651
Illegal Remote Service Dial-up
An expected error occurred when Cu-
min-M dialed up the NRS Center.
Software bug
No action is required because only the
count is logged
670 D
Engine startup error
The machine engine, controlled by the
BICU (Base Image Control Unit), was
operating incorrectly when the ma-
chine was switched on or returned to
normal operation from the energy save
mode.
Check the connections between BICU and
controller
BICU defective
Controller board defective
PSU defective
672 B
Controller startup error
After power on, the line between the
controller and the operation panel did
not open for normal operation.
After normal startup, communication
with the controller stopped.
Controller stalled
Controller installed incorrectly
Controller board defective
Operation panel harness disconnected or
defective
SC700: Peripherals
720 D
Finisher transport motor error
The encoder pulse of the finisher trans-
port motor does not change state
(high/low) within 600 ms and does not
change after 2 retries.
Finisher transport motor defective
Transport motor harness disconnected, or
defective
Finisher main board defective
721 B
Finisher jogger motor error
Service Mode