0F30
0F31
ASIC (Mandolin) for system control
could not be detected. After the PCI
configuration, the device ID for the
ASIC could not be checked.
ASCI (Mandolin) for system control is de-
fective
Interface between North Bridge and AGPI
is defective
Replace the mother board
0F41
The read/write check done for resi-
dent RAM on the mother board could
not be done correctly.
Memory device defective
Replace the mother board
50B1
Could not initialize or read the bus
connection.
Bus connection defective, loose
SSCG defective
Replace the mother board
50B2
Value of the SSCG register is incor-
rect.
Bus connection loose, defective
SSCG defective
Replace the mother board
834 D Self-diagnostic error 9: Optional Memory RAM DIMM
5101
The write/verify check for the option-
al RAM chip on the engine mother
board gave an error.
Controller defective
Mother board defective
838 D
Self-diagnostic Error: Clock Generator
Replace the controller board
A verify error occurred when setting data
was read from the clock generator via the
I2C bus.
839 D
Serial Flash
Replace the controller board
A read/write operation on the Software
Status Register failed.
850 B
Net I/F error
Duplicate IP addresses.
Illegal IP address.
IP address setting incorrect
NIB (PHY) board defective
Controller board defective
4. Troubleshooting
276