operating normally, the receipt of a
power line interrupt signal from the
FLUTE serial driver was detected, or
BREAK signal from the other station was
detected.
• Connection to EFI controller loose
925 B
NetFile Function Error
• The NetFile file management on the HDD cannot
be used, or a NetFile management file is corrupted
and operation cannot continue.
• The HDDs are defective and they cannot be de-
bugged or partitioned, so the Scan Router functions
(delivery of received faxes, document capture,
etc.), Fabric services, and other network functions
cannot be used.( HDD status codes displayed on
the debug console are described below.)
• HDD defective
• Power supply to machine
cut occurred while writ-
ing data to HDD
• Software error
• Please refer to the de-
tailed descriptions below
for recovery procedures.
HDD Status Codes Displayed on Debug Console
Display Meaning
(-1) HDD not connected
(-2) HDD not ready
(-3) No level
(-4) Partition type incorrect
(-5) Error returned during level read or check
(-6) Error returned during level read or check
(-7) “filesystem” repair failed
(-8) “filesystem” mount failed
(-9) Drive does not answer command
(-10) Internal kernel error
(-11) Size of drive is too small
(-12) Specified partition does not exist
Service Mode
281