1. Feed SP1000
2. Drum SP2000
3. Process SP3000
5. Mode SP5000
6. Periphs SP6000
7. Data Log SP7000
8. Data Log2 SP8000
9. Etc. SP9000
1. Press or to select the group, and then press [#Enter].
• The 2-line display is rotational. If you press with “1.Feed” displayed, the display will jump
to "9. Etc.", the last selection. Similarly, if you press with “9.Etc” displayed, the display will
jump to “1.Feed”, the first selection.
2. While referring to the Service Program Mode Tables, press or to select the SP that you
want to change, and then press [#Enter].
• If you see > or >> to the right of a selection name, this means a menu sublevel exists.
3. Follow one of the procedures below to change a setting.
To change a single-digit number setting:
• Press [#Enter]. A number replaces the value at the cursor.
• Press or to increase or decrease the number.
• Press [#Enter]. The number selected on the 2nd line replaces the number above.
• Press [Escape] to return to the previous level.
To change a multiple-digit number setting
• Press or to move the cursor to the digit that you want to change.
• Press [#Enter]. A number replaces the value at the cursor.
• Press or to increase or decrease the number.
• Press [#Enter]. The number selected on the 2nd line replaces the number above.
• Repeat the procedure to enter numbers for the other digits.
• Press #(Escape) to return to the previous level.
To select an item from a list
5. Service Tables