5. FASTENING SETTING mode (Type S)
5-16
a. T/T Offset Maximum
The upper limit tolerance of the T/T offset value
< Calculation method >
063Eh (hexadecimal) = 1598 (decimal) = Rated torque
In the case of the default value
00C8h (hexadecimal) = 200 (decimal)
200/1598 x 100 = 12.5%
Recommended setting (Default value) = 00C8h
b. T/T Calibration Minimum
The lower limit tolerance of the T/T calibration value is set.
The calculation method is the same as above. The value is -2% of the rated torque.
Recommended setting (Default value) = 061Eh
c. T/T Calibration Maximum
The upper limit tolerance of the T/T calibration value is set.
The calculation method is the same as above. The value is +2% of the rated torque.
Recommended setting (Default value) = 065Eh
d. Brake time
Braking time is set. Increasing setting values corresponds to increasing the braking time.
Recommended setting (Default value) = 00C8h
e. Trouble socket release speed
Socket release speed used in the case of stopping due to TROUBLE is set. Increasing setting values
corresponds to increasing the release speed.
Recommended setting (Default value) = 0100h
f. Trouble socket release time
Socket release time used in the case of stopping due to TROUBLE is set. Increasing values corresponds to
increasing the time.
Recommended setting (Default value) = 0032h