EasyManuals Logo

Siemens SCALANCE W738-1 M12 Configuration Guides

Siemens SCALANCE W738-1 M12
616 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Result
The auto save function is enabled.
Further notes
You save changes to the configuration in the Trial mode with the write startup-config
command.
You disable the function with the no auto-save command.
You can display the status of this function and other information with the show device
informationcommand.
4.4.3.2 no auto-save
Description
With this command, you disable the auto save function.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
no auto-save
Result
The auto save function is disabled. The Trial mode is activated.
Further notes
You enable the function with the auto-save command.
You can display the status of this function and other information with the show device
informationcommand.
You save changes to the configuration in the Trial mode with the write startupconfig
command.
Configuration
4.4 Configuration Save & Restore
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 105

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals