cli> or cli#
Syntax
Call the command without parameters:
show authlog
or
Call up the command with the following parameters:
show authlog [{ info | warning | critical }]
The parameters have the following meaning:
Parameter Description
info All log entries of the category "Information" are displayed.
warning All log entries of the category "Warning" are displayed.
critical All log entries of the category "Critical" are displayed.
Result
The content of the logbook is displayed.
12.1.1.2 show events config
Description
This command shows the current configuration for forwarding the messages of the various
event types.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli> or cli#
Syntax
Call the command without parameters:
show events config
Result
The current configuration of the events display is displayed.