Result
The frequency band for the WLAN interface is specified.
Further notes
You display the setting with the show wlan basic <wlan 0/X> command.
7.1.5.51 wlan guard interval (access point)
Description
With this command, you specify the send pause that must be kept to between two transferred
OFDM symbols.
Note
This command is available only in access point mode.
Requirement
The IEEE 802.11n transmission standard is enabled.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan guard interval { GI400 | GI800 }
The parameters have the following meaning:
Parameters Description
GI400 The send pause is 400 ns (default)
GI800 The send pause is 800 ns
Result
The function is enabled and the send pause set.
Further notes
You display the setting with the show wlan advanced-11n <wlan 0/X> command.
Network structures
7.1 WLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 253

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals