EasyManuals Logo

Siemens SCALANCE W738-1 M12 Configuration Guides

Siemens SCALANCE W738-1 M12
616 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #588 background imageLoading...
Page #588 background image
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call the command without parameters:
clear logbook
Result
The content of the logbook is deleted.
12.1.4 fault report ack
Description
With this command, you acknowledge (delete) the messages of the "Cold/Warm start" event.
Requirement
You are in the Privileged EXEC mode.
The command prompt is as follows:
cli#
Syntax
Call up the command with the following parameter:
fault report ack <fault-state-id>
The parameter has the following meaning:
Parameters Description Range of values/note
fault-state-id ID of the mes‐
sage
Enter the ID of the message for the "Cold/Warm Start" event.
To obtain the ID, use the "show events faults status"
command.
Result
The message is acknowledged.
Diagnostics
12.1 Diagnostics
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
588 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish