wlan ipcf-mc cycle-time <ms (32-512)>
The parameter has the following meaning:
Parameter Description Range of values / note
ms Cycle time in millisec‐
onds (ms)
32 ... 512
Result
The cycle time is configured.
Further notes
You display the setting with the show wlan ipcf-mc command.
5.6.2.5 wlan ipcf-mc mgmt-scan-period (client)
Note
The command is only available if the SCALANCE W700 device supports iPFC-MC or the
function can be enabled.
iPCF-MC is enabled with the aid of the following KEY-PLUGs:
W780 iFeatures (MLFB 6GK5 907-8PA00)
W740 iFeatures (MLFB 6GK5 907-4PA00)
Description
With this command, you the time for the background scan interval as a multiple of the update
time.
Requirement
The SCALANCE W700 device is in client mode
You are in the WLAN configuration mode.
The command prompt is as follows:
cli(config-wlan)#
Syntax
Call up the command with the following parameters:
wlan ipcf-mc mgmt-scan-period <num-of-cycles (1-10)>
Functions specific to SCALANCE
5.6 iPCF-MC
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
144 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals