5.5.2.6 wlan ipcf-ht scan-mode (access point)
Note
This command is only available with the following KEY-PLUG:
W780 iFeatures (MLFB 6GK5 907-8PA00)
Description
With this command, you configure the scanning mode of the logged on clients.
Requirement
The SCALANCE W700 device is in access point mode.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan ipcf-ht scan-mode {all-channels|next-channel}
The parameters have the following meaning
Parameter Description
all-channels The client scans all permitted channels and selects the access point with the
best signal strength and connects to it.
next-channel The client scans the next channel from its permitted channel list. If an access
point is there, it connects to it. If it does not find an access point on this channel,
it scans the next channel.
Result
The scanning mode of the logged on clients is configured.
Further notes
You display the setting with the show wlan ipcf-ht command.
Functions specific to SCALANCE
5.5 iPCF-HT
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 137

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals