5.2.2.1 web-session-timeout
Description
With this command, you enable the automatic logoff and you configure the timeout setting for
the WBM.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
web-session-timeout[seconds(60-3600)]
The parameter has the following meaning:
Parameter Description Range of values / note
seconds Time in seconds until automatic logout
after the last entry
60 … 3600
Default: 900
Result
The time is configured and automatic logout is enabled.
Further notes
You disable automatic logoff with the no web-session-timeout command.
You display the current timeout setting with the show web-session-timeout command.
5.2.2.2 no web-session-timeout
Description
With this command, you disable the automatic logoff.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Functions specific to SCALANCE
5.2 WBM
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 115

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals