7.1.5.7 wlan ampdu bytes-limit
Description
With this command, you specify the maximum size of the AMPDU data packet in bytes.
Note
This command is available only in access point mode.
Requirement
The IEEE 802.11n transmission standard is enabled.
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan ampdu bytes-limit <bytes(1024-65535)>
The parameter has the following meaning:
Parameters Description Range of values / note
bytes Size of the AMPDU data packet in bytes 1024 to 65535 bytes
Default: 50000 bytes
Result
The size for the AMPDU data packets is specified.
Further notes
You display the setting with the show wlan advanced-11n <wlan 0/X> command.
7.1.5.8 wlan ampdu frames-limit
Description
With this command, you specify the number of individual data packets (frames) grouped
together in one AMPDU data packet.
Network structures
7.1 WLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
216 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals