EasyManuals Logo

Siemens SCALANCE W738-1 M12 Configuration Guides

Siemens SCALANCE W738-1 M12
616 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #326 background imageLoading...
Page #326 background image
Further notes
You can reset the setting to the default with the no spanning-tree (properties) command.
You display these settings and other information with the commands that start with show
spanning tree ....
7.3.4.2 no spanning-tree
Description
With this command, you reset the various properties of the spanning tree function to the default
value:
The default values are as follows:
Parameter Default value
cost if dynamic calculation of the path costs is not enabled:
200000 for physical interfaces
199999 for port channels
disable The spanning tree function is enabled on the interface
link-type
point-to-point
The connection is configured as full-duplex
shared
in all other cases
portfast disabled
port-priority 128
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
no spanning-tree {cost|disable|link-type|portfast|port-priority}
The parameters have the following meaning:
Parameter Description
cost Keyword for the costs of the port for calculating the lowest-cost path.
disable Enables the interface for spanning tree.
link-type Connection status of the following network segment
portfast Disables the PortFast function.
port-priority Keyword for the priority of the interface
Network structures
7.3 Spanning Tree
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
326 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals