EasyManuals Logo

Siemens SCALANCE W738-1 M12 Configuration Guides

Siemens SCALANCE W738-1 M12
616 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #528 background imageLoading...
Page #528 background image
Further notes
You display the settings with the show wlan security <vapX 0/Y> command.
11.3.5.3 vap security default-key (access point)
Description
With this command, you specify which WEP key from the key table is used for encryption.
Note
This command is available only in access point mode.
Requirement
You are in the Interface Configuration mode of the VAP interface.
The command prompt is as follows:
cli (config-if-vapX-0-Y)#
Syntax
Call up the command with the following parameters:
vap security default-key <index (1-4)>
The parameter has the following meaning:
Parameters Description Range of values / note
index Index of the key table 1...4
Result
The WEP key is specified.
Further notes
You display the settings with the show wlan security <vapX 0/Y> command.
Security and authentication
11.3 WLAN
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
528 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals