7.3.4.11 no spanning-tree mst hello-time
Description
With this command, you reset the hello time after which the bridge sends its configuration
BPDUs to the default value.
The default value is 2 seconds.
Requirement
You are in the interface configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no spanning-tree mst hello-time
Result
The setting for the hello time is reset to the default value.
Further notes
You can configure the setting for the hello time with the spanning-tree mst hello-
time command.
You display this setting and other information with the commands that start with show
spanning tree ....
7.3.5 Commands in the MSTP configuration mode
This section describes commands that you can call up in the MSTP configuration mode.
In the Global configuration mode, enter the spanning-tree mst configuration
command to change to this mode.
If you exit the MSTP configuration mode with the exit command, you return to the Global
configuration mode.
If you exit the MSTP configuration mode with the end command, you return to the Privileged
EXEC mode.
Network structures
7.3 Spanning Tree
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
334 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals