The interface is an IP interface.
You are in the Interface configuration mode
The command prompt is as follows:
cli(config-if-$$)#
Syntax
Call up the command with the following parameters:
no ipv6 dhcp client request {dns-server-address | domain-name | sntp-
server-address | option <code (1-100)>}
The parameters have the following meaning:
Parameter Description Range of values / note
dns-server-
address
IPv6 address of the DNS server -
domain-name Domain name -
sntp-server-
address
IPv6 address of the SNTP server -
option Keyword for the option code -
code ID of the DHCPV6 option Specify the required ID of the
DHCPv6 option.
1 ... 100
Result
The required configuration parameter is removed.
Further notes
You configure the request with the ipv6 dhcp client request command.
8.5 DHCP server
You can operate the device as a DHCP server. This allows IP addresses to be assigned
automatically to the connected devices. The IP addresses are either distributed dynamically
from an address band (pool) you have specified or a specific IP address is assigned to a
particular device.
Network protocols
8.5 DHCP server
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 387

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals