The parameters have the following meaning:
Parameter Description
all Monitoring of all power supply connectors by PROFINET.
l1-l2 Monitoring of the power supply connectors L1 and L2 by PROFINET.
l1-poe Monitoring of the power supply connectors L1 and PoE by PROFINET.
l2-poe Monitoring of the power supply connectors L2 and PoE by PROFINET.
Result
Monitoring of the power supply by PROFINET is configured.
Further notes
You can display the current setting with the show events faults config command.
12.1.6.11 send test mail
Description
With this command, you send an e-mail according to the currently configured SMTP settings.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call the command without parameters:
send test mail
Result
An e-mail according to the currently configured SMTP settings is sent.
Further notes
You can display the current SMTP settings with the show events smtp-server command.
Diagnostics
12.1 Diagnostics
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
600 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals