Requirement
The name of the file is specified
You are in the LOADSAVE configuration mode.
The command prompt is:
cli(config-loadsave)#
Syntax
Call up the command with the following parameters:
tftp load{showfiles|filetype<filetype>}
The parameters have the following meaning:
Parameter Description Range of values / note
showfiles Shows the available files -
filetype Keyword for a file type to be loaded -
filetype Name of the file type max. 100 characters
Result
The file types are displayed or the file is downloaded to the device.
Further notes
You configure the name of the file with the tftp filename command.
With the "show loadsave files" command, you can display the file types.
4.2.5.4 tftp save
Description
With this command, you copy a file from the file system of the device to a TFTP server. The
TFTP protocol is used for the transfer. You can also display a list of available files.
Requirement
The name of the file is specified
You are in the LOADSAVE configuration mode.
The command prompt is:
cli(config-loadsave)#
Syntax
Call up the command with the following parameters:
tftp save {showfiles|filetype<filetype>}
Configuration
4.2 Load and Save
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 91

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals