cli(config)#
Syntax
Call up the command with the following parameters:
coordinates height <meter>
The parameter has the following meaning:
Parameter Description Range of values / note
meter Input box for the height coordinate max. 32 characters
To use spaces in the entry, enter
the height coordinate in quotes:
coordinates height "123
456"
Result
The height coordinate is created.
4.1.10.2 coordinates latitude
Description
With this command, you enter a latitude coordinate.
Requirement
You are in the Global Configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
coordinates latitude <latitude>
The parameter has the following meaning:
Parameter Description Range of values / note
latitude Input box for the latitude coordinate max. 32 characters
To use spaces in the entry, enter
the latitude coordinate in quotes:
coordinates latitude
"123 456"
Configuration
4.1 System
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
66 Configuration Manual, 09/2017, C79000-G8976-C324-08

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals