Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call up the command with the following parameters:
no snmp community index <CommunityIndex>
The parameter has the following meaning:
Parameter Description Range of values / note
CommunityIndex Name of the community max. 32 characters
Result
The details of an SNMP community are deleted.
Further notes
You configure the details of an SNMP community with the snmp community index
command.
You show the details of an SNMP community with the show snmp community command.
You show the status information of the SNMP communication with the show snmp command.
8.6.2.8 snmp engineid migrate
Description
With this command, you enable the SNMPv3 user migration.
If the function is enabled, an SNMP engine ID is generated that can be migrated. You can
transfer configured SNMPv3 users to a different device. If you enable this function and load
the configuration of the device on another device, configured SNMPv3 users are retained.
Requirement
You are in the Global configuration mode.
The command prompt is as follows:
cli(config)#
Syntax
Call the command without parameters:
Network protocols
8.6 SNMP
SCALANCE W770/W730 acc. to IEEE 802.11n Command Line Interface
Configuration Manual, 09/2017, C79000-G8976-C324-08 419

Table of Contents

Other manuals for Siemens SCALANCE W738-1 M12

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SCALANCE W738-1 M12 and is the answer not in the manual?

Siemens SCALANCE W738-1 M12 Specifications

General IconGeneral
BrandSiemens
ModelSCALANCE W738-1 M12
CategoryWireless Access Point
LanguageEnglish

Related product manuals